Jotafloor Topcoat

Product description

Jotafloor Topcoat is a two-pack epoxy floor coating offering good chemical resistance, durability and available in a variety of colours. May also be used as a final coating on Jotafloor Screed.

Recommended use

Areas requiring a dust free, hard wearing and aesthetically pleasing floor coating such as:

Warehouses Garages Workshops Production areas

 

Excellent adhesion to primed concrete, mortar, screed and a limited number of other surfaces make Jotafloor Topcoat ideal for many uses in light to medium industrial areas.

Film thickness and spreading rate

                                                                                 Minimum                       Maximum                      Typical

Film thickness, dry (µm)                                        40                                    60                                  50

Film thickness, wet (µm)                                       80                                   120                               100

Theoretical spreading rate (m²/l)                       12,5                                 8,3                                  10

Physical properties

Colour Available in Jotun Multicolor tinting system.

Solids (vol %)* 50 ± 2

Flash point 25ºC ± 2 (Setaflash)

VOC 448 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Glossy

Gloss retention Fair

Water resistance Very good

Abrasion resistance Very good

Solvent resistance Excellent

Chemical resistance Excellent Check chemical resistance values on Jotun chemical resistance chart.

Flexibility Good

*Measured according to ISO 3233:1998 (E)

Surface preparation

All concrete damaged by exposure to chemicals, contaminated by any substance or unsound in any way, shall be removed to expose sound concrete.

Coated surfaces

Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.

Other surfaces

Concrete surface preparation by using dust free captive blasting units, grinding equipment, sand blasting or high pressure water jetting is critical to achieving the right surface profile prior to paint application. Contact your local Jotun office for more information.

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper drying. The moisture content in the concrete should not exceed 4 % (by weight). The coating should not be exposed to oil, chemicals or mechanical stress until fully cured.

Application methods

Spray Use airless spray

Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Roller May be used. However when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness.

Application data

Mixing ratio (volume) 4:1

Mixing 4 parts Comp. A (base) to be mixed thoroughly with 1 part Jotafloor TC, Comp. B (curing agent).

Induction time 30 minutes.

Pot life (23°C) 8 hours. (Reduced at higher temp.)

Thinner/Cleaner Jotun Thinner No. 17

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm² 2100 psi)

Nozzle tip 0.46 - 0.58 mm (0.018-0.023")

Spray angle 40 - 80º

Filter Check to ensure that filters are clean.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Normal hardener

 

Substrate temperature

10°C

23°C

40°C

Surface dry

2,5 h

1,5 h

0,5 h

Through dry

14 h

6,5 h

3 h

Cured

Dry to recoat, minimum 1

14 d

 

14 h

7 d

 

7 h

3 d

 

3 h

1. The surface should be free from chalking and contamination prior to application. Best intercoat adhesion occurs when the subsequent coat is applied before the preceding coat has cured. If this is exceeded it may be necessary to roughen the surface.

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

Typical paint system

Jotafloor Sealer

1 x 40 µm

(Dry Film Thickness)

Jotafloor Topcoat

1 - 2 x 50 µm

(Dry Film Thickness)

Other systems may be specified, depending on area of use

Test Certificates

Determination of Bond strength to host concrete - BS 1881 : Part 207

Determination of Crack Bridgeability - ASTM C884

Determination of Rapid Chloride Permeability - AASHTO T277 Determination of Water Permeability - DIN 1048 Determination of Acid or Alkali Reaction - ASTM D543 Determination of Weather or Salt Spray Test - N.F.C. Standard Determination of Impact Resistance - ISO 6272 Determination of Shore 'A' hardness - ASTM D2240

Determination of Taber Abrasion (1,000 Cycles) - ASTM D4060

Determination of Toxicity - BS 6920

Determination of Flame Spread - ASTM D1360

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition.Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

16 litres Comp. A in a 20 litre container and 4 litres Jotafloor TC, Comp. B (curing agent) in a 5 litre container. 4 litres Comp. A in a 5 litre container and 1 litre Jotafloor TC, Comp. B (curing agent) in a 1 litre container.

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 

Скачать: 
.