A high-build, one-component Inert Multipolymeric Matrix coating designed to provide corrosion protection of structures exposed to extreme high and/or extreme low temperatures.
Corrosion protection of insulated and non-insulated carbon steel and stainless steel with dry operating surface temperatures that can range from cryogenic to above 650 ºC (intermittent 720 ºC) including cyclic services in temperatures between -185 ºC and 540 ºC. Can be applied on hot substrates (up to 400 ºC - ref. Application Guide). Especially suited for preventing corrosion under insulation during construction and shut down/low temperature periods.
453 gms/ltr UK-PG6/23(97). Appendix 3
*Measured according to ISO 3233:1998 (E)
Hong Kong rules:
Category of paints - Other vessel coatings; VOC 424 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.95; Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Cleanliness: Power tool cleaning to min. St 2, mill scale free (ISO 8501-1:2007) and a roughness between 35 - 50 microns. Improved surface treatment (blast cleaning to Sa 2½) will improve the performance.
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. The coating should not be exposed to oil, chemicals or mechanical stress until fully cured.
Thinner/Cleaner Jotun Thinner No. 21/Jotun Thinner No. 7
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi)
Nozzle tip 0.38-0.53 mm (0.015-0.021")
Filter Check to ensure that filters are clean.
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature |
10°C |
15°C |
23°C |
40°C |
100°C |
Surface dry |
8-10 h |
6 h |
2 h |
2 h |
0,5 h |
Through dry 2 |
24h |
24 h |
6 h |
4 h |
1 h |
Dry to recoat, minimum 1 |
24h |
24 h |
6 h |
4 h |
1 h |
The surface should be free from chalking and contamination prior to application.
Exposure to extreme temperature, below 0 °C and above 400 °C, should be avoided before the coating is through dry.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
Jotatemp 650 |
2 x 125 µm |
(Dry Film Thickness) |
Optional system: Jotatemp 650 |
3 x 125 µm |
(Dry Film Thickness) |
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
5 litre unit.
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.