Marathon is a high solids, two-component epoxy coating reinforced with glass flakes.
Steel and concrete structures subject to aggressive exposure, both atmospheric and mechanical. Offers extremely good protection against corrosion and has outstanding abrasion resistance. Proved records for use in high pressure vessels. Can be used as corrosion protection for subsea installations at high temperature areas (christmas trees and manifolds) in combination with cathodic protection.
Under certain conditions Marathon may be applied in a thickness corresponding to a DFT up to 500 µm provided prior approval from Jotun TSS and accompanying updated application instructions. For further information please contact your local Jotun office.
APAS approved to specification 0213
NORSOK M-501, system 7A (TI report 30270 KA02)
NORSOK M-501, system 7C (SINTEF report F21006 (>150°C))
110 gms/ltr UK-PG6/23(97). Appendix 3
Gloss Glossy
*Measured according to ISO 3233:1998 (E)
Hong Kong rules:
Category of paints - Other vessel coatings; VOC 210 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.26 (A+B); Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Cleanliness: Blast cleaning to min. Sa 2 ½ (ISO 8501 1:2007). Roughness: using abrasives suitable to achieve Grade Medium G (50 - 85 µm, Ry5) (ISO 8503-2).
Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure proper drying. The coating should not be exposed to oil, chemicals or mechanical stress until cured.
Mixing 3 parts Comp. A (base) to be mixed thoroughly with 1 part Marathon, Comp. B (curing agent)
Pot life (23°C) 1 hour (reduced at higher temperatures)
Thinner/Cleaner Jotun Thinner No. 17
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi)
Nozzle tip 0.63 - 1.09 mm (0.025-0.043")
Filter Filters to be removed prior to spraying.
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature |
10°C |
23°C |
40°C |
Surface dry |
14 h |
5,5 h |
3 h |
Through dry |
32 h |
12 h |
6 h |
Cured |
14 d |
7 d |
3 d |
Dry to recoat, minimum Dry to recoat, maximum 1 |
32 h 5d |
12h 3d |
6h 2d |
1. The surface should be free from chalking and contamination prior to application. If the maximum dry to recoat time is exceeded, please contact Jotun for advice.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
On Sa 2½ :
For extended corrosion protection, on Sa 2½ :
Barrier |
1 x 25 µm * |
(Dry Film Thickness) |
Marathon |
300 µm + 200 µm |
(Dry Film Thickness) |
For aggressive chemical exposure, on Sa 2½ :
Tankguard HB |
1 x 50 µm |
(Dry Film Thickness) |
Marathon |
300 µm + 200 µm |
(Dry Film Thickness) |
For subsea structures, NORSOK M-501, system 7A, on Sa 2½ :
* It is important that Barrier is applied with DFT 25 µm, and therefore Barrier must be thinned 25-40 %.
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
20 litre unit: 15 litres Comp. A (base) in a 20 litre container and 5 litres Marathon, Comp. B (curing agent) in a 5 litre container
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.