Alkyd Topcoat

Product description

Alkyd Topcoat is an alkyd based topcoat for both exterior and interior use. This product is part of a complete system which has a low flame spread certificate.

 

image

 

Recommended use

Alkyd topcoat in a traditional alkyd system is suitable for steel and woodwork. The product has good weather stability and colour stability.

 

image

 

Film thickness and spreading rate

 

                                                                                         Minimum      Maximum        Typical

Film thickness, dry (µm)                                                  20                  40                  30

Film thickness, wet (µm)                                                 45                  90                  70

Theoretical spreading rate (m²/l)                                  22                  11                 14,7

Comments

Hong Kong rules:         Category of paints - Marine maintenance coatings; VOC 435 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A;  Specific gravity: 1.13;

Both VOC and Specific gravity values provided are typical values, subject to changes when

different colour involved.

 

image

 

Physical properties

Colour                                 White, Std 38, Std 49, Std 137 and Black

Solids (vol %)*                    44 ± 2

 

Flash point                          36ºC ± 2 (Setaflash)

 

VOC                                     3,63 lbs/gal (435 gms/ltr) USA-EPA Method 24

410 gms/ltr UK-PG6/23(97). Appendix 3

 

Gloss                                     Glossy

Gloss retention                   Good

Water resistance                Limited

Abrasion resistance           Fair

Flexibility                            Good

*Measured according to ISO 3233:1998 (E)

 

image

Surface preparation

 

All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.

 

Coated surfaces

Clean, dry and undamaged compatible primer. Please contact your local Jotun office for more information.

 

Other surfaces

The coating may be used on other substrates. Please contact your local Jotun office for more information.

 

image

 

Condition during application

The temperature of the substrate should be minimum 3ºC above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure correct drying.

 

image

 

Application methods

Spray                 Use airless spray or conventional spray

Brush                 Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Roller                 May be used. However when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness.

 

image

 

Application data

Mixing ratio (volume)                     Single pack.

 

Thinner/Cleaner                              Jotun Thinner No. 2

Guiding data airless spray

Pressure at nozzle                      15 MPa (150 kp/cm², 2100 psi)

Nozzle tip                                     0.38 - 0.53 mm (0.015 - 0.021")

Spray angle                                 40 - 80°

Filter                                             Check to ensure that filters are clean.

 

image

 

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

 

Substrate temperature

5°C

10°C

23°C

40°C

Surface dry

5 h

4 h

3h

1 h

Through dry

25h

14 h

7h

3 h

Dry to recoat, minimum Dry to recoat, maximum 1

36h

18 h

16 h

12 h

1.    The surface should be dry and free from any contamination prior to application of the subsequent coat.

 

image

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc.  A complete system can be described on a system sheet, where all parameters and special conditions could be included.

 

 

Typical paint system

 

Alkydprimer or Pilot Primer

Alkyd Topcoat

2 x 40 µm

1 x 30 µm

(Dry Film Thickness)

(Dry Film Thickness)

 

Note: To obtain full coverage, an extra coat may be necessary.

Other systems may be specified, depending on area of use

 

image

 

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

 

image

 

Handling

Handle with care. Stir well before use.

 

image

 

Packing size

20 litre container

 

image

 

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 

 