Balloxy HB Lumi is a two pack surface tolerant high solids epoxy mastic coating. This product utilises luminous pigments to aid application and inspection.
Balloxy HB Lumi is intended for use in water ballast tanks, on steel behind insulation, in cofferdams and areas with condensation and where blast cleaning may not be possible and on hydrojetted surface still being moist.
Gloss Semigloss
*Measured according to ISO 3233:1998 (E)
All surfaces should be clean and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Cleanliness: Power tool cleaning to min. St 2, mill scale free (ISO 8501-1:2007). Improved surface treatment (blast cleaning to Sa 2½) will improve the performance. In case of waterjetting the flash rust degree shall not exceed M (moderate) in SSPC and NACE standards for waterjetted surfaces.
Clean, dry and undamaged approved shopprimer.
Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information. For maintenance UHPWJ to WJ2 (NACE No.5/SSPC-SP 12) or Power tool cleaning to min. St 2 for rusted areas
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure proper drying. The coating should not be exposed to oil, chemicals or mechanical stress until cured.
Hydrojetting of steel surface makes a wet surface. The surrounding air must have a relative humidity not exceeding 85
%. Before painting the surface shall not be glossy with moisture, but can have a patchy appearance.
Pot life (23°C) 2 hours (Reduced at higher temp.)
Thinner/Cleaner Jotun Thinner No. 17
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi.).
Nozzle tip 0.53 - 0.79 mm (0.021 - 0.031").
Filter Check to ensure that filters are clean
Too much solvent results in lower sag resistance and slower cure.
If extra solvent is necessary, this should be added after mixing of the two components.
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature |
10°C |
23°C |
40°C |
Surface dry |
8 h |
4h |
2 h |
Through dry |
24 h |
10h |
4 h |
Cured |
14 d |
7d |
2 d |
Dry to recoat, minimum Dry to recoat, maximum 1 |
24 h |
10h |
4 h |
1. Provided the surface is free from chalking and other contamination prior to application, there is normally no overcoating time limit. Best intercoat adhesion occurs, however, when the subsequent coat is applied before preceding coat has cured. If the coating has been exposed to direct sunlight for some time, special attention must be paid to surface cleaning and mattening/removal of the surface layer in order to obtain good adhesion.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
Balloxy HB Lumi |
1 x 175 µm |
(Dry Film Thickness) |
Balloxy HB Light |
1 x 175 µm |
(Dry Film Thickness) |
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
15 litres Comp. A (base) in a 20 litre container and 3 litres Comp. B. (curing agent) in a 5 litre container. Packing may vary from country to country according to local requirements.
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.