Hardtop CA

Product description

Hardtop CA is a two-pack acrylic, isocyanate free topcoat with good gloss and colour retention.

Recommended use

As topcoat over an epoxy primer where a durable, high gloss finish is required in aggressive atmospheric exposure.

Film thickness and spreading rate

                                                                            Minimum                  Maximum                     Typical

Film thickness, dry (µm)                                 60                                125                               75

Film thickness, wet (µm)                               100                               210                              125

Theoretical spreading rate (m²/l)                 10                                  4,8                                8

Physical properties

Colour According to colour card and Multicolor tinting system (MCI)

Solids (vol %)* 60 ± 2

Flash point 28ºC ± 2 (Setaflash)

VOC 340 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Glossy

Gloss retention Good

Water resistance Very good

Abrasion resistance Good

Solvent resistance Good

Chemical resistance Good

Flexibility Excellent

*Measured according to ISO 3233:1998 (E)

Surface preparation

All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.

Coated surfaces

Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.

Other surfaces

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 5°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure correct drying.

Application methods

Spray Use airless spray

Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Roller May be used for small areas.

Application data

Mixing ratio (volume) 9:1

Mixing 9 parts of Comp. A (base) to be mixed thoroughly with 1 part Hardtop CA, Comp. B (curing agent).

Pot life (23°C) 4 hours (Reduced at higher temp.).

Thinner/Cleaner Jotun Thinner No. 7 or Jotun Thinner No. 17

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi).

Nozzle tip 0.33-0.46 mm (0.013-0.018").

Spray angle 40-80°

Filter Check to ensure that filters are clean.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

 

Substrate temperature

5°C

10°C

23°C

40°C

Surface dry

6 h

4 h

2,5 h

2 h

Through dry

72h

36 h

5h

5 h

Cured

28d

14 d

12 d

3 d

Dry to recoat, minimum Dry to recoat, maximum 1

72h

36 h

5h

5 h

1. The surface must be free from any chalking or any other contamination and if necessary, sufficiently roughened prior to application.

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

 

 

Typical paint system

 

Barrier

Jotacote Universal

Hardtop CA

1 x 75 µm

1 x 150 µm

1 x 75 µm

 

(Dry Film Thickness) (Dry Film Thickness) (Dry Film Thickness)

Note: To obtain full coverage an extra coat may be necessary, especially for signal colours in red, orange and yellow.

Other systems may be specified, depending on area of use

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

20 litre unit: 18 litres Comp. A (base) in a 20 litre container and 2 litres Hardtop CA, Comp. B (curing agent) in a 3 litre container.

5 litre unit: 4,5 litres Comp. A (base) in a 5 litre container and 0,5 litres Hardtop CA, Comp. B (curing agent) in a 1 litre container.

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 