Jotafloor SF Primer

Product description

Jotafloor Sealer is a transparent two-pack epoxy sealer/primer exhibiting excellent penetration properties to ensure good adhesion between Jotafloor products and most masonry surfaces.

Recommended use

As a sealer/primer for subsequent Jotafloor products or for use independently as a dust binder for concrete floors.

Film thickness and spreading rate

                                                                      Minimum                    Maximum                        Typical

Film thickness, dry (µm)                             30                                 50                                    40

Film thickness, wet (µm)                            80                                130                                  100

Theoretical spreading rate (m²/l)            12,5                               7,7                                   10

Comments

Substrate porosity and profile will affect practical coverage rates.

Physical properties

Colour Clear

Solids (vol %)* 40 ± 2

Flash point 25ºC ± 2 (Setaflash)

VOC 515 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Glossy

Water resistance Very good

Solvent resistance Excellent

Chemical resistance Excellent Check chemical resistance values in Jotafloor chemical resistance chart.

Flexibility Good

*Measured according to ISO 3233:1998 (E)

Surface preparation

All concrete damaged by exposure to chemicals, contaminated by any substance or unsound in any way, shall be removed to expose sound concrete.

Coated surfaces

Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.

Other surfaces

Concrete surface preparation by using dust free captive blasting units, grinding equipment, sand blasting or high pressure water jetting is critical to achieving the right surface profile prior to paint application. Contact your local Jotun office for more information.

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper drying. The moisture content in the concrete should not exceed 4 % (by weight). The coating should not be exposed to oil, chemicals or mechanical stress until fully cured.

Application methods

Spray Use airless spray or conventional spray

Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Roller May be used. However when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness.

Application data

Mixing ratio (volume) 4:1

Mixing 4 parts Comp. A (base) to be mixed thoroughly with 1 part Jotafloor Sealer, Comp.

B (curing agent). NO PART MIXING.

Induction time 30 minutes.

Pot life (23°C) 8 hours (reduced at higher temp.)

Thinner/Cleaner Jotun Thinner No. 17

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm² 2100 psi)

Nozzle tip 0.46 - 0.58 mm (0.018-0.023")

Spray angle 40-80°

Filter Check to ensure that filters are clean

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Substrate temperature

10°C

23°C

40°C

Surface dry

2 h

1 h

0.5 h

Through dry

14 h

6,5 h

3 h

Cured

14 d

7 d

2 d

Dry to recoat, minimum

8 h

4 h

1,5 h

1. The surface should be free from chalking and contamination prior to application. Best intercoat adhesion occurs when the subsequent coat is applied before the preceding coat has cured.

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

 

Typical paint system

As dust binder:

Jotafloor Sealer

 

Nominal

 

For coloured finish:

Jotafloor Sealer

 

1 x 40 µm

 

(Dry Film Thickness)

Jotafloor Topcoat

or

Jotafloor Sealer

2 x 50 µm

 

1 - 2 x 40 µm

(Dry Film Thickness)

 

(Dry Film Thickness)

Jotafloor Coating

or

Jotafloor Sealer

1 x 300 µm

 

1 - 2 x 40 µm

(Dry Film Thickness)

 

(Dry Film Thickness)

Jotafloor SL Universal

1 x 2000 - 4000 µm

(Dry Film Thickness)

Note: Thickness of the finished system will vary depending on use of the finished floor. Consult your local Jotun Office for advice.

Other systems may be specified, depending on area of use

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition.Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

16 litres Comp. A (base) in a 20 litre container and 4 litres Jotafloor Sealer, Comp. B (curing agent) in a 5 litre container. or

4 litres Comp. A (base) in a 5 litre container and 1 litres Jotafloor Sealer, Comp. B (curing agent) in a 1 litre container.

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.