Jotaprime 500 is a two-pack, anti-abrasion, polyamine cured epoxy-based primer for both immersed and non-immersed areas.
Anti-corrosive coating for newbuilding situations as well as for maintenance on both above and below water areas excluding water ballast tanks. To be used on steel alone or in combinations with other coatings. Aluminium versions for use below water.
Minimum Maximum Typical
Film thickness, dry (µm) 100 200 150
Film thickness, wet (µm) 140 280 210
Theoretical spreading rate (m²/l) 7,1 3,55 4,73
For DFTs below 150 µm, thinner should be used.
Colour Red, Aluminium and aluminium red toned, Grey
Solids (vol %)* 72 ± 2
Flash point 28ºC ± 2 (Setaflash)
VOC 2,34 lbs/gal (280 gms/ltr) USA-EPA Method 24
245 gms/ltr UK-PG6/23(97). Appendix 3
Gloss Semigloss
Gloss retention Fair
Water resistance Good
Abrasion resistance Good
Solvent resistance Good
Chemical resistance Fair
Flexibility Good
*Measured according to ISO 3233:1998 (E)
Hong Kong rules:
Category of paints - Other vessel coatings; VOC 280 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.45 kg/ltr (A+B); Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Bare steel
Cleanliness: Blast-cleaning to Sa 2½ (ISO-8501-1:2007). Power tool cleaning to min. St 2 (ISO 8501-1:2007) may be acceptable for minor touch-up work, subjected to exposure conditions.
Shopprimed steel
Clean, dry and undamaged approved shopprimer.
Coated surfaces
Clean, dry and undamaged compatible primer. Old existing coating systems can be overlapped, but feathering of edges should be carried out. Please contact your local Jotun office for more information.
Other surfaces
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum -5°C and minimum 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure proper drying. Do not use heated air until the solvents have evaporated from the paint film to avoid surface drying and solvent entrapment. The coating should not be exposed to strain until cured.
Spray Use airless spray
Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.
Roller May be used. However when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness.
Mixing ratio (volume) 4:1
Mixing 4 parts Comp. A (base) to be mixed thoroughly with 1 part Jotaprime 500, Comp. B (curing agent).
Pot life (23°C) 1 hour (Reduced at higher temperature)
Thinner/Cleaner Jotun Thinner No. 17
Guiding data airless spray
Pressure at nozzle 15 MPa min (150 kp/cm², 2100 psi.)
Nozzle tip 0.43-0.64 mm (0.017-0.025").
Spray angle 40-80°
Filter Check to ensure that filters are clean.
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature Surface dry |
-5°C 20h |
0°C 14h |
5°C 6 h |
10°C 4h |
23°C 2h |
Through dry 1 |
48 h |
30 h |
16h |
10h |
4 h |
Cured |
21 d |
14d |
10d |
7 d |
|
Dry to recoat, minimum |
48 h |
30 h |
16h |
10h |
4 h |
Substrate temperature |
40°C |
||||
Surface dry Through dry 1 |
|
||||
Cured |
3 d |
||||
Dry to recoat, minimum |
2 h |
||||
Dry to recoat, maximum |
1 Provided the surface is free from chalking and other contamination prior to application, there is normally no overcoating time limit. Best intercoat adhesion occurs, however, when the subsequent coat is applied before preceding coat has cured. If the coating has been exposed to direct sunlight for some time, special attention must be paid to surface cleaning and mattening/removal of the surface layer in order to obtain good adhesion.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
Non-immersed areas:
Jotaprime 500 2 x 125 µm (Dry Film Thickness)
Hardtop AS/XP 1 x 50 µm (Dry Film Thickness)
Immersed areas:
Jotaprime 500 Aluminium 2 x 150 µm (Dry Film Thickness)
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
20 litre unit: 16 litres Jotaprime 500, Comp. A (base) in a 20 litre container and 4 litre Jotaprime 500, Comp. B (curing agent) in a 5 litre container
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.