Penguard FC is a high build, two component polyamide cured epoxy coating. This product is tintable in a wide range of colours in Jotuns Multicolour Industry system.
Penguard FC is an epoxy finish coat to be used when cosmetic appearance of an epoxy finish is acceptable. It can also be used as an anti corrosive primer in mild to medium environment for steel and concrete above water areas or as an intermediate coat in more corrosive environment.
For application below typical film thickness, 160 microns WFT, up to 5% thinning may be needed to obtain proper flow and film forming.
Gloss Semigloss
*Measured according to ISO 3233:1998 (E)
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Cleanliness: Blast cleaning to Sa 2½ (ISO 8501-1:2007). Roughness: using abrasives suitable to achieve grade Fine to Medium G (30-85 µm, Ry5) (ISO 8503-2)
Clean, dry and undamaged approved shopprimer.
Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.
For aluminium and galvanized surface; degreasing, light abrading or sand sweeping.
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum 0°C and minimum 3°C above the dew point of the air. The temperature and the relative humidity should be measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper drying. With forced ventilation, avoid heated air at first as this may cause surface drying and solvent entrapment. The coating should not be exposed to oil, chemicals or mechanical stress until fully cured.
Mixing 4 parts Comp. A (base) to be mixed thoroughly with 1 part Comp. B (curing agent) 15 minutes prior to use.
Pot life (23°C) 2 hours. (Reduced at higher temp.)
Thinner/Cleaner Jotun Thinner No. 17
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi.)
Nozzle tip 0.46 - 0.69 mm (0.018-0.027")
Filter Check to ensure that filters are clean.
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature |
0°C |
5°C |
10°C |
23°C |
40°C |
Surface dry |
9 h |
8 h |
7 h |
2,5h |
1 h |
Through dry |
36h |
24h |
15 h |
7,5h |
2 h |
Cured |
- |
14d |
8 d |
4 d |
2 d |
Dry to recoat, minimum Dry to recoat, maximum 1 |
36h |
24h |
15 h |
7,5h |
4 h |
1. Provided the surface is free from chalking and other contamination prior to application, there is normally no overcoating time limit. If the coating has been exposed to direct sunlight for some time, special attention must be paid to surface cleaning and mattening/removal of the surface layer in order to obtain good adhesion.
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
Penguard FC can be applied direct to metal or over a wide range of primers including:
Barrier |
Penguard Midcoat |
Primastic Universal |
Jotamastic 87 |
Penguard Express |
Penguard Tie Coat 100 |
Jotacote Universal |
Penguard HB |
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
16 litres Comp. A (base) in a 20 litre container and 4 litres Comp. B (curing agent) in a 5 litre container or
4 litres Comp. A (base) in a 5 litre container and 1 litre Comp. B (curing agent) in a 1 litre container
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.