A high solid, two component, abrasion resistant epoxy coating which may be applied in high film thickness.
A universal primer specifically designed for use in new construction situations, on steel to be exposed to harsh conditions. May be used by itself or in combination with other compatible products as part of a complete coating system. Offers excellent protection against corrosion and has excellent abrasion resistance. If a cosmetic finish is required, it should be used together with a topcoat.
Thinning may be necessary at lower DFT.
200 gms/ltr UK-PG6/23(97). Appendix 3
Gloss Semigloss
*Measured according to ISO 3233:1998 (E)
Hong Kong rules:
Category of paints - Other vessel coatings; VOC 240 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.37 (A+B); Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.
All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.
Cleanliness: Blast cleaning to min. Sa 2½ (ISO 8501-1:2007) or for previously coated surfaces UHPWJ to WJ2 (NACE No.5/SSPC-SP 12). Roughness: using abrasives suitable to achieve grade Fine to Medium G (30-85 µm, Ry5) (ISO 8503-2). Power tool cleaning to min. St 2 (ISO 8501-1:2007) may be acceptable, subject to exposure.
Clean, dry and undamaged approved shopprimer.
Clean, dry and undamaged compatible primer. Please contact your local Jotun office for more information.
The coating may be used on other substrates. Please contact your local Jotun office for more information.
The temperature of the substrate should be minimum -5°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper drying. The coating should not be exposed to water, chemicals or mechanical stress until cured.
Mixing 3 parts Comp. A (base) to be mixed thoroughly with 1 part Penguard Pro, Comp. B (curing agent).
Pot life (23°C) 1 hour (reduced at higher temperatures).
Thinner/Cleaner Jotun Thinner No. 17
Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi)
Nozzle tip 0.58-0.79 mm (0.023-0.031")
Filter Check to ensure that filters are clean
Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:
Good ventilation (Outdoor exposure or free circulation of air)
Typical film thickness
One coat on top of inert substrate
Substrate temperature Surface dry |
-5°C 10 h |
0°C 8 h |
10°C 6h |
23°C 3h |
40°C 1h |
Through dry 1 |
38h |
22h |
12 h |
6 h |
4 h |
Cured |
21d |
12 d |
10 d |
7 d |
|
Dry to recoat, minimum 2 |
24h |
16h |
7 h |
3 h |
2 h |
Dry to recoat, maximum 3 |
14d |
14d |
14 d |
14 d |
10 d |
Substrate temperature |
5°C |
||||
Surface dry Through dry 1 |
7h 18h |
||||
Cured |
14 d |
||||
Dry to recoat, minimum 2 |
10 h |
||||
Dry to recoat, maximum 3 |
14 d |
The earliest time for exposure to mechanical strain, i.e. to walk on the coated surface.
The earliest time for recoating with the same generic type of paint. Note that the paint film is not hard at this time and can not withstand mechanical strain.
Provided the surface is free from chalking and other contamination prior to application, there is normally no overcoating time limit. Best intercoat adhesion occurs, however, when the subsequent coat is applied before preceding coat has cured. If the coating has been exposed to direct sunlight for some time, special attention must be paid to surface cleaning and mattening/removal of the surface layer in order to obtain good adhesion
The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.
Typical paint system |
||
On Sa 2½: Barrier Plus |
1 x 60 µm |
(Dry Film Thickness) |
Penguard Pro Hardtop Optima |
1 x 150 µm 1 x 75 µm |
(Dry Film Thickness) (Dry Film Thickness) |
Other systems may be specified, depending on area of use
The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.
Handle with care. Stir well before use.
20 litre unit: 15 litres Comp. A (base) in a 20 litre container and 5 litres Penguard Pro, Comp. B in a 5 litre container.
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.