Pilot ACR

Product description

A quick drying high build, one component acrylic finish.

Recommended use

Can be used as a single coat system in atmospheric corrosivity category C2. The product can also be used as a topcoat on various primers.

Can be used at temperatures down to -15 °C.

Film thickness and spreading rate

                                                                             Minimum                 Maximum                   Typical

Film thickness, dry (µm)                                      80                           120                              120

Film thickness, wet (µm)                                    145                          220                              220

Theoretical spreading rate (m²/l)                      6,9                           4,6                                4,6

Physical properties

Colour According to colour card and Multicolor tinting system (MCI)

Solids (vol %)* 55 ± 2

Flash point 25ºC ± 2 (Setaflash)

VOC 398 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Semigloss

Gloss retention Good

Abrasion resistance Good

Solvent resistance Limited

Chemical resistance Good

Flexibility Good

*Measured according to ISO 3233:1998 (E)

Hong Kong rules:

Category of paints - Marine maintenance coatings; VOC 400 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.49; Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.

Surface preparation

All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.

Bare steel

Cleanliness: Power tool cleaning to min. St 2, mill scale free (ISO 8501-1:2007). Improved surface treatment (blast cleaning to Sa 2½) will improve the performance.

Coated surfaces

Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information. For maintenance UHPWJ to WJ2 (NACE No.5/SSPC-SP 12) or Power tool cleaning to min. St 2 for rusted areas

Other surfaces

For aluminium and galvanized surface; degreasing, light abrading or sand sweeping.

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 3ºC above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure correct drying.

Application methods

Spray Use airless spray (thin 5%)

Brush Use a suitable brush. Care must be taken to achieve the specified dry film thickness.

Roller May be used, but is not recommended for first coat on bare metal. Care must be taken to achieve the specified dry film thickness.

Application data

Mixing ratio (volume) Single pack

Thinner/Cleaner Jotun Thinner No. 7

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi)

Nozzle tip 0.38-0.53 mm (0.015-0.021")

Spray angle 40-65°

Filter Check to ensure that filters are clean.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Substrate temperature

-10°C

0°C

10°C

23°C

40°C

Surface dry

30 min

30min

15min

15min

15min

Through dry

7h

7 h

5 h

4 h

4h

Dry to recoat, minimum

3 h

3 h

2 h

1 h

1h

 

Substrate temperature Surface dry

Through dry

 

5°C

20 min

7 h

 

 

Dry to recoat, minimum

 

3 h

Dry to recoat, maximum

 

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

Typical paint system

1) Pilot ACR 1 x 120 µm (Dry Film Thickness)

or

2) Pilot QD primer

1 x 80 µm

(Dry Film Thickness)

Pilot ACR

1 x 80 µm

(Dry Film Thickness)

Other systems may be specified, depending on area of use

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

5 litre container or 20 litre container

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 

Скачать: 
.