SeaLion Tiecoat is a three-pack silicone elastomeric tiecoat. IMO Anti-fouling System Convention compliant (AFS/CONF/26).

Recommended use

To promote adhesion of SeaLion Repulse. Constitutes a part of the SeaLion fouling release coating (FRC) system.

Film thickness and spreading rate

                                                                                  Minimum               Maximum             Typical

Film thickness, dry (µm)                                                                                                         90

Film thickness, wet (µm)                                                                                                      150

Theoretical spreading rate (m²/l)                                                                                        6,4

Physical properties

Colour Light Red

Solids (vol %)* 58 ± 2

Flash point 24ºC ± 2

VOC 3,33 lbs/gal (400 gms/ltr) USA-EPA Method 24

378 gms/ltr UK-PG6/23(97). Appendix 3

*Measured according to ISO 3233:1998 (E) Hong Kong rules:

Category of paints - Antifouling sealer coatings; VOC 400 gms/ltr HK EPD method (Ready to use); Exempt

compound - N/A; Specific gravity: 1 gms/ltr (A+B+C); Both VOC and Specific gravity values provided are typical values, subject to changes when different colour involved.

Surface preparation

Coated surfaces

To be applied on a clean, dry Safeguard Universal ES. The primer must be fresh, not applied more than three days prior to the SeaLion Tiecoat application.

 

Other surfaces

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate must be minimum 0°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. The air temperature must be minimum 0ºC. Good ventilation is usually required in confined areas to ensure proper drying. Relative humidity during application and drying should be minimum 30%.

Application methods

Spray Use airless spray.

Other Care should be taken to avoid overspray onto other coated areas.

Application data

Mixing ratio (volume) 16,7 : 0,6 : 0,9

Mixing 16,7 litres Comp. A (base) to be mixed thoroughly with 0,6 litres SeaLion Tiecoat, Comp. B (Curing agent). Then add 0,9 litre SeaLion Tiecoat Comp. C (catalyst) and mix thoroughly again.

Pot life (23°C)

1 hour

0,5 hours (40ºC)

Thinner/Cleaner Do not thin.

Cleaner Jotun Thinner No. 7

Guiding data airless spray

Pressure at nozzle 15 MPa (211 kp/cm², 3000 psi).

Nozzle tip 0.38 mm - 0.53 mm (0.015" - 0.021")

Filter Check to ensure that filters are clean.

Note Sagging may occur if application procedure and specification are not followed.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Substrate temperature

0°C

10°C

15°C

23°C

40°C

Surface dry

12h

8 h

6 h

4 h

2 h

Dry to recoat, minimum

24h

18 h

16 h

12 h

6 h

Dry to recoat, maximum

4 d

4 d

4 d

4 d

4 d

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

Recommended type of primer:

SeaLion Tiecoat MUST only be applied on Safeguard Universal ES. Application on any other substrate can give adverse effects on adhesion.

The SeaLion FRC system consists of SeaLion Tiecoat and SeaLion Repulse. SeaLion Tiecoat is applied to anticorrosive layer as adhesion promotion layer for SeaLion Repulse.

Muki EPS (optional)

Anticorrosive primer system suitable for purpose Safeguard Universal ES

SeaLion Tiecoat

SeaLion Repulse

1 x 30 µm (Dry Film Thickness) 1 x 200 µm (Dry Film Thickness) 1 x 100 µm (Dry Film Thickness) 1 x 90 µm (Dry Film Thickness) 1 x 150 µm (Dry Film Thickness)

Storage

The product must be stored below 25°C and in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

18,2 litre unit: 16,7 litre Comp. A (base) in a 20 litre container, 0,6 litre SeaLion Tiecoat, Comp. B in a 0,75 litre container and 0,9 litre SeaLion Tiecoat Comp. C in a 1 litre container.

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 