Tankguard Special Topcoat is a two-component phenolic epoxy coating with high resistance to a wide range of chemicals and solvents.

Recommended use

Interior of tanks. Tankguard Special Topcoat is the final coat in the Tankguard Special coating system. A separate resistance list is available.

Film thickness and spreading rate

                                                                                           Minimum                      Maximum                         Typical

Film thickness, dry (µm)                                                  80                                  150                                    100

Film thickness, wet (µm)                                                125                                 240                                    160

Theoretical spreading rate (m²/l)                                   7,9                                  4,2                                     6,3

Physical properties

Colour Grey

Solids (vol %)* 63 ± 2

Flash point 25ºC ± 2 (Setaflash)

VOC 240 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Semigloss

Water resistance Very good

Solvent resistance Excellent

Chemical resistance Excellent

Flexibility Fair

*Measured according to ISO 3233:1998 (E)

Surface preparation

Clean and dry surface. Surface contamination is to be removed by detergents and fresh water cleaning.

Other surfaces

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 10°C and at least 3°C above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is required in confined areas to ensure proper drying. The coating should not be exposed to oil, chemicals or mechanical stress until cured.

Application methods

Spray Use airless spray

Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Application data

Mixing ratio (volume) 3,7 parts Comp. A (base) to be mixed thoroughly with 1 part Comp. B (curing agent)

Induction time 20 minutes.

Pot life (23°C) 3 hours (Reduced at higher temp.)

Thinner/Cleaner Jotun Thinner No. 23

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm², 2100 psi)

Nozzle tip 0.46-0.69 mm (0.018-0.027")

Spray angle 40-80°

Filter Check to ensure that filters are clean.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Substrate temperature

10°C

15°C

23°C

40°C

Surface dry

16 h

10 h

5,5h

2 h

Through dry

36 h

16 h

8,5h

4 h

Cured

Dry to recoat, minimum 2

Dry to recoat, maximum 1

- d         52h

 

18d

14d

 

36h

 

12d

7d

 

        20 h

 

7d

3 d

 

10h

 

4d

 

  1. The surface should be free from chalking and contamination prior to application. If the maximum dry to recoat time is exceeded, please contact Jotun for advice.

  2. In order to achieve full product resistance, a combined total of 14 days curing at minimum 15ºC is required during build period.

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

 

Typical paint system

 

 

Tankguard Special Primer Tankguard Special Mid-Coat Tankguard Special Topcoat

100 µm

100 µm

100 µm

 

(Dry Film Thickness) (Dry Film Thickness) (Dry Film Thickness)

For touch up, stripe coating and minor repair work, Tankguard TU can be used.

Other systems may be specified, depending on area of use

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

20 litre unit: 14.7 litres Comp. A (base) in a 20 litre container and 4 litres Comp. B (curing agent) in a 5 litre container Packing may vary from country to country according to local requirements.

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 