Vinyguard Silvergrey 88

Product description

Vinyguard Silvergrey 88 is a quick drying, modified vinyl primer.

Recommended use

As a tie coat or as a sealer for an antifouling system to be compliant with IMO Anti-fouling System Convention (AFS/CONF/26). Can also be used as a primer/touch-up primer under alkyd and acrylic coatings for steel structures.

Film thickness and spreading rate

                                                                                                      Minimum                      Maximum                      Typical

Film thickness, dry (µm)                                                             35                                   100                                  80

Film thickness, wet (µm)                                                            95                                   260                                 210

Theoretical spreading rate (m²/l) 10,9 3,8 4,8

Comments

When used as a sealer coat in 35µm dry film thickness, 5-10% additional thinning may be necessary.

Hong Kong rules: Category of paints - Antifouling sealer coatings; VOC 540 gms/ltr HK EPD method (Ready to use); Exempt compound - N/A; Specific gravity: 1.14;

Both VOC and Specific gravity values provided are typical values, subject to changes when

different colour involved.

Physical properties

Colour Aluminium, Aluminium Red toned

Solids (vol %)* 38 ± 2

Flash point 28ºC ± 2 (Setaflash)

VOC 530 gms/ltr UK-PG6/23(97). Appendix 3

Gloss Flat

Water resistance Very good

Abrasion resistance Good

Solvent resistance Limited

Chemical resistance Good

Flexibility Good

*Measured according to ISO 3233:1998 (E)

Surface preparation

All surfaces should be clean, dry and free from contamination. The surface should be assessed and treated in accordance with ISO 8504.

Bare steel

Cleanliness: Blast-cleaning to Sa 2½ (ISO-8501-1:2007). Power tool cleaning to min. St 2 (ISO 8501-1:2007) may be acceptable, subject to exposure conditions.

Shopprimed steel

Clean, dry and undamaged approved shopprimer.

Coated surfaces

Clean, dry and undamaged compatible primer. Contact your local Jotun office for more information.

Other surfaces

The coating may be used on other substrates. Please contact your local Jotun office for more information.

Condition during application

The temperature of the substrate should be minimum 3ºC above the dew point of the air, temperature and relative humidity measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure correct drying.

Application methods

Spray Use airless spray or conventional spray

Brush Recommended for stripe coating and small areas, care must be taken to achieve the specified dry film thickness.

Roller May be used for small areas but not recommended for first primer coat, however when using roller application care must be taken to apply sufficient material in order to achieve the specified dry film thickness.

Application data

Mixing ratio (volume) Single pack.

Thinner/Cleaner Jotun Thinner No. 7

Guiding data airless spray

Pressure at nozzle 15 MPa (150 kp/cm² 2100 psi)

Nozzle tip 0.46-0.69 mm (0.018-0.027")

Spray angle 40-80°

Filter Check to ensure that filters are clean.

Drying time

Drying times are generally related to air circulation, temperature, film thickness and number of coats, and will be affected correspondingly. The figures given in the table are typical with:

  • Good ventilation (Outdoor exposure or free circulation of air)

  • Typical film thickness

  • One coat on top of inert substrate

Substrate temperature

5°C

10°C

23°C

40°C

Surface dry

30 min

20 min

15 min

10 min

Through dry

Dry to recoat, minimum 1

Dry to recoat, maximum 2

4h

 

4h

3h

 

3h

2h

 

2h

1.5h

 

2h

The given data must be considered as guidelines only. The actual drying time/times before recoating may be shorter or longer, depending on film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. A complete system can be described on a system sheet, where all parameters and special conditions could be included.

Typical paint system

Below water:

Vinyguard Silvergrey 88 3 x 80 µm (Dry Film Thickness)

Above water:

Vinyguard Silvergrey 88 2 x 80 µm (Dry Film Thickness)

Pioner Topcoat 1 x 50 µm (Dry Film Thickness) alternatively

Pilot II 1 x 40 µm (Dry Film Thickness)

Antifouling systems:

See recommendations in the antifouling technical data sheets.

Other systems may be specified, depending on area of use

Storage

The product must be stored in accordance with national regulations. Storage conditions are to keep the containers in a dry, cool, well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed.

Handling

Handle with care. Stir well before use.

Packing size

20 litre container

Health and safety

Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not breathe or inhale mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

 

Скачать: 
.